Variac Portable Enclosed Models
Portable, metered or unmetered cased units are available in many models for laboratory and test bench applications. Each unit consists of a variable autotransformer and an overload protector.
A voltmeter, ammeter and/or wattmeter are available on some models. The output circuit is protected by either a thermal overload protector, resettable from the front panel or by easily accessible and replaceable fuses.
Shielding is provided to reduce stray fields sufficiently to provide an overall accuracy of 3% of full scale.
A double pole on-off switch interrupts both sides of the AC line. Where dual range meters are used, make before break range switches permit switching under load. A convenient carrying handle is provided on all models.
| SINGLE PHASE, 120V, 50-60Hz INPUT |
|
|
|
|
|
|
|
|
|
|
RATED
CURRENT
AMPERES |
MAX
CURRENT
AMPERES |
KVA |
OUTPUT
VOLTAGE
RANGE |
TYPE NO. |
METER
RANGE
AMPS |
METER
RANGE
WATTS |
METER
RANGE
VOLTS |
2 OR 3 WIRE
CORD AND
RECEPTACLE |
NET
WEIGHT
(Ibs) |
SHIP
WEIGHT
(Ibs) |
W |
H |
D |
| 5.0 |
6.5 |
0.78 |
0-140 |
W5MT ~* |
- |
- |
- |
3 |
8 |
15 |
4.875 |
6.562 |
4.375 |
| 5.0 |
6.5 |
0.78 |
0-140 |
W5MT3 ~* |
- |
- |
- |
3 |
8 |
15 |
4.875 |
6.562 |
4.375 |
| 5.0 |
6.5 |
0.78 |
0-140 |
WSMT3VM |
- |
- |
150 |
3 |
8 |
19 |
4.875 |
6.562 |
4.375 |
| 5.0 |
6.5 |
0.78 |
0-140 |
W5MT3A |
1/5 |
- |
150 |
3 |
11 |
19 |
6.750 |
9.50 |
5.250 |
| 5.0 |
6.5 |
0.78 |
0-140 |
W5MT3W |
- |
150/750 |
150 |
3 |
12 |
19 |
6.750 |
9.50 |
5.250 |
| 5.0 |
6.5 |
0.78 |
0-140 |
W5MT3AW |
1/5 |
150/750 |
150 |
3 |
12 |
21 |
11.937 |
8.625 |
5.375 |
| 7.1 |
9.2 |
1.1 |
0-120 |
W5LMT3 |
- |
- |
- |
3 |
8 |
18 |
4.875 |
6.562 |
4.375 |
| 10.0 |
11.0 |
1.32 |
0-140 |
W8MT3 ! |
- |
- |
- |
3 |
10 |
16 |
5.375 |
7.0 |
6.125 |
| 10.0 |
11.0 |
1.32 |
0-140 |
W8MT3VM |
- |
- |
150 |
2 |
10 |
16 |
5.375 |
7.0 |
6.125 |
| 10.0 |
13.0 |
1.56 |
0-140 |
W10MT ~ |
- |
- |
- |
3 |
16 |
24 |
6.750 |
9.5 |
5.250 |
| 10.0 |
13.0 |
1.56 |
0-140 |
W10MT3 ~ |
- |
- |
- |
3 |
16 |
24 |
6.750 |
9.5 |
5.250 |
| 10.0 |
13.0 |
1.56 |
0-140 |
W 10MT3A |
2/10 |
- |
150 |
3 |
18 |
30 |
8.625 |
11.937 |
5.375 |
| 10.0 |
13.0 |
1.56 |
0-140 |
W10MT3W |
- |
300/1500 |
150 |
3 |
18 |
30 |
8.625 |
11.937 |
5.375 |
| 18.1 |
23.0 |
2.6 |
0-140 |
W20MT3A |
20 |
- |
150 |
3 |
27 |
34 |
8.625 |
11.937 |
5.375 |
| 18.1 |
23.0 |
2.6 |
0-140 |
W20MT3 ~ |
- |
- |
- |
3 |
20 |
23 |
8.625 |
11.937 |
5.375 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Single Phase 240V 50-60Hz INPUT |
|
|
|
|
|
|
|
|
|
|
| 2.0 |
2.6 |
0.62 |
0-280 |
W5HMT ~ |
- |
- |
- |
2 |
8 |
8 |
4.875 |
6.562 |
4.375 |
| 4.0 |
5.2 |
1.25 |
0-280 |
W10HMT |
- |
- |
- |
2 |
15 |
15 |
6.750 |
9.50 |
5.250 |
| 4.0 |
5.2 |
1.25 |
0-280 |
W10HMT3 |
- |
- |
- |
3 |
15 |
15 |
6.750 |
9.50 |
5.250 |
| 8.0 |
10.4 |
2.50 |
0-280 |
W20HMT3 ~ |
- |
- |
- |
3 |
27 |
27 |
8.625 |
11.937 |
5.375 |
| 8.0 |
10.4 |
2.50 |
0-280 |
W20HMT3A |
10 |
- |
300 |
3 |
25 |
25 |
8.625 |
11.937 |
5.375 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ~ UL Listed * CSA Approved ! 60Hz Only |
|
|
|
|
|
|
|
|
|
|
|